鉗形表

KEW 2413R真有效值漏電鉗形表

KEW 2413R真有效值漏電鉗形表

- 68mm大鉗口設計,可同時夾住三或四條(三相)電纜以進行漏電電流量測
- 配備頻率濾波開關,有效消除諧波影響
- 雙向類比輸出端子,方便連接記錄器或外部設備
- 最小解析度達0.1mA,適用於高精度量測需求
詳細介紹

Specification
AC A (50/60Hz) 200mA/2/20/200/1000A
±2.5%rdg±5dgt (200mA/2/20A)
±3.0%rdg±5dgt (200A, 0 to 500A)
±5.5%rdg (501 to 1000A)
AC A (WIDE) 200mA/2/20/200/1000A
±1.8%rdg±5dgt [50/60Hz] (200mA/2/20A)
±2.0%rdg±5dgt [50/60Hz] (200A, 0 to 500A)
±5.0%rdg [50/60Hz] (501 to 1000A)
Crest factor 3.0 or less
Conductor size φ68mm max.
Frequency response 40Hz to 1kHz
Output Waveform :AC200mV against the maximum value of each range (1000A range is 100mV)
Recorder   :DC200mV against the maximum value of each range (1000A range is 100mV)
Applicable standards IEC 61010-1 CAT III 300V Pollution degree 2
IEC 61010-2-032
Power source 6F22 (9V) × 1
*Continuous measuring time: Approx. 60 hours
Dimension 250(L) × 130(W) × 50(D)mm
Weight Approx. 600g (including battery)
Accessories 9094 (Carrying Case)
6F22 × 1 Instruction Manual
Optional Accessories 7073 (2WAY Output Cord)